FOR INTERNAL INFINITY WATER HEATERS
Direct Flue This option is used when the Infinity water heater is mounted against an exterior wall. The components consist of a 90 deg bend adaptor, wall terminal and one wall plate.

Extended Flue This option can be used when the water heater is mounted against an internal wall and flueing needs to extend horizontally to exit an external wall. Rinnai Infinity direct Flueing components must be used for this purpose, together with extension pieces and bends as required. Total Flue length can be up to 9 metres long and a maximum of 3 bends can be used. Over 1.5m vertical requires a condensate trap.

Vertical Flue This option can be used when the water heater needs to be flued vertically through the roof. Vertical Flueing components with extension pieces and condensate trap (if necessary) are used for this purpose. If the total flue height is more than 1.5 metres a condensate trap is required. Total Flue length can be up to 9 metres long and a maximum of 3 bends can be used.

Plan View The Infinity can be installed virtually anywhere using a wall or roof terminals, extension pieces (mounted vertically and horizontally), bends, adaptors and condensate traps as required. 
|